Baer Energie- & Messtechnik GmbH
Home Information Products News Software Contact Sitemap
    

M-Bus / RS485 System





M-Bus Technical data and description
 

 M-Bus / Meter Bus flexible communication system overview (Filesize1.7M )




M-Bus Logger
 
M-Bus Logger

M-Bus Logger
    

The M-Bus Logger has a modular design in top-hat rail installation.

The following versions are available:

- Load profile:     4000 values ( ca. 40 day with 15 min. registration period).
- Billing data:     for 16 resets (e.g.: 16 month-values).


Order-Number:
11913     2 Reed-Inputs, without supply voltage
12405     2 S0-Inputs, supply voltage 15VDC to 24VDC
11792     2 S0-Inputs, supply voltage 115VAC
11821     2 S0-Inputs, supply voltage 230VAC

Programming and data retrieval by M-Bus (according to DIN EN 1434-3).

 Product Description (Filesize 1.1M)





M-Bus Repeater / Master / Minirepeater / Minimaster
 






    

M-Bus Master

The standard M-Bus master is used in medium to large M-Bus systems. Its specific functions are implemented with the following elements:

  

Power supply module:
The M-Bus master can power up to 250 terminals with a maximum current requirement of 1.5mA each. In cascaded operation, the master ca itself be the terminal for a higher-level bus segment and support the power supply. Current limitation protects the master from an overload or short circuit on the M-Bus. The cable length can be up to 10 km.

   Interfaces:
-  

M-Bus (active) for connecting the terminals (output)

-  

RS232 service interface for parameterization and error analysis of the terminals connected

-  

Exchangeable interface card for data transmission to the control centre: RS232 or M-Bus passive (input)

M-Bus Master / Repeater / Minirepeater / Minimaster

The M-Bus repeater is a special version of standard M-Bus master with follow interfaces:

-   Output: M-Bus active
-   RS232 service interface
-   Input: M-Bus passive for connecting the terminals

M-Bus Master / Repeater
in control housing for top hat rail installation
PDF Product Description (Filesize 549K)
PDF Data Sheet (Filesize 252K)
PDF Flyer (Filesize 258K)

M-Bus Master / Repeater
in control housing for wall mounting
PDF Product Description (Filesize 252K)





M-Bus Converter Box
 
Konvertierboxox
    

The converter box is used to adapt physically two interfaces and to separate them galvanicly. It is configured as follows: Two interface slots can be used to plug in the following modules as required:
RS232, 20mA (passive), 20mA (active), M-Bus (passive), M-Bus (active), RS485

PDF Product Description (Filesize 823K)

Konvertierboxox
    

The converter box ConvBox is a digital level converter in control housing for top rail installation with one RS232 interface. The box is used to adapt physically two interfaces and to separate them galvanicly.
Two interface slots can be used to plug in the following modules as required: M-Bus (active for up to 25 loads, passive), RS485 and 20mA/CS (active, passive).

PDF Product Description (Filesize 483K)
PDF Flyer (Filesize 265K)




Converter M-Bus to 20mA (active)
 
Umsetzer

Umsetzer Kabelversion

Umsetzer Hutschienenmontage
    

The converter is used to adapt physically two interfaces and to separate them galvanicly  (level converter without protocol conversion):
- M-Bus-Interface passive: function "Slave"
- 20mA-Interface active: networking of one or more meters.

The converter can be designed as a:

Version 1    

(for Landis+Gyr ZMD meter only):
with supply voltage (e.g.: 230VAC or 110VAC) to connecting up to 8 meters with 20mA-Interface.

 
Version 2

(for Landis+Gyr ZMD meter only):
without supplyvoltage to connecting of one meter with 20mA-Interface.

 
Version 3

(universal):
without supplyvoltage to connecting of every one meter with 20mA-Interface

 
Version 4    

Compact housing for wall or top hat rail installation:
with supplyvoltage (e.g.: 230VAC or 110VAC) to connecting up to 8 meters with 20mA-Interface.


PDF Product Description (Filesize 306K)





Converter M-Bus to RS485 2 wires
 
Converter M-Bus to RS485

Converter M-Bus to RS485 / DIN-RAIL
    

The converter is used to adapt physically two interfaces  (level converter without protocol conversion):

  • M-Bus-Interface passive: function „Slave“
  • RS485 2 wires interface:
    networking of one or more meters (max. 8)
PDF Product Description four cables for universal use (Filesize 232K)
PDF Product Description top hat rail installation/BFC-Bus (Filesize 219K)




AMR Interface Landis+Gyr E350
 
ComModule
    

The AMR Interface is designed for use with the Landis+Gyr E350 meters. More...





M-Bus / Modbus Interface Module XC
 
EMH-XC-Interface Module
    

The Interface Module XC is designed for use with the EMH LZQJ-XC and DMTZ-XC meters. More...





COM Listener
 
COMListener
    

The COM Listener is used to test a RS232 connection between two devices: transparent check for TxD and RxD lines

PDF Product Description (Filesize 212K)





M-Bus modules (passive and active)
 
Module
    

The M-Bus modules are used to equip devices with an M-Bus bus interface.

There are active (master) and passive (slave) modules available.


 
Relays
Modems
Data
Logger
Software
M-Bus/RS485
  Overview
  M-Bus Logger
  M-Bus Master /
Repeater
  Converter Box
  Converter
M-Bus / 20mA
  M-Bus /
RS485-2
  AMR Interface
L+G E350
  Interface
Module
LZQJ-XC
  Module active
  Module passive
Special
Product
Family
Modules
Service
 

Top of Page

 Home    |    Information    |    Products    |    News    |    Service    |    Contact us    |    Sitemap

Copyright © Baer Energie- & Messtechnik GmbH

Last Update 28.03.2019 at 14:53:25.